Issue

3rd party integrations with Pelco Sarix platform cameras and NET5400 Series Encoders rely on a unique URL friendlyName for seamless integration.



 

Product Line

Pelco Video Management

Environment

  • Sarix Cameras and NET5400 Series Encoders All versions
  • 3rd Party integrations with Pelco Sarix platform cameras and NET5400 Series Encoders

Cause

Endura Utilities is unable to change the URL "friendlyName" for Sarix platform cameras and NET5400 Series Encoders

Resolution

Example of NET5404T Encoder

  1. Open the NET5404T Webpage
  2. Login with Username admin and Password admin (default) then click Log In

     
  3. Click on Settings

     
  4. Click on the System tab and change the Device Name
  5. Click on Save
  6. Click on Reboot Encoder