SM5200 fails to reimage with Clonezilla screen or fails to start with proper Boot device

Issue

1. The SM5200 fails to boot to the Pelco Recovery screen and instead boots to a Clonezilla screen


2.  Error message on boot up generates error message and does not boot with SM5200 firmware

Product Line

Pelco Video Management

Environment

  • SM5200 All Versions

Cause

The SM5200 1st Boot Priority has changed to [UEFI USB]

Resolution

  1. Reboot the SM5200
  2. Upon power up, tap the Delete key every other second until the BIOS menu appears
  3. Tab over to the Boot menu
  4. Arrow to 1st Boot Priority and press Enter then select USB and press Enter



Press F4 to Save & Exit then select Yes